Peptide blend · GH axis research
Tesamorelin and ipamorelin blend
A two-component preparation containing tesamorelin and ipamorelin, each a separate synthetic peptide with its own formula and reference mass.
- Compound type
- Peptide blend
- Research area
- GH axis
What it is
This entry is a blend rather than a single molecule: two peptides supplied together in one preparation. Nothing about the combination changes the chemistry of either component, and each is characterized separately.
Tesamorelin is the larger of the two, with the molecular formula C221H366N72O67S, an average molecular weight of 5135.78 g/mol and a monoisotopic mass of 5132.72, indexed in PubChem under CID 16137828. See the tesamorelin profile for its structure, origin and laboratory literature.
Ipamorelin is a small synthetic peptide with the molecular formula C38H49N9O5, an average molecular weight of 711.85 g/mol and a monoisotopic mass of 711.39, indexed in PubChem under CID 9831659. See the ipamorelin profile for its structure, origin and laboratory literature.
Structure and chemistry
The two components sit at opposite ends of the synthetic peptide range, which is the main practical fact about the blend. Tesamorelin is a long peptide of more than five thousand daltons containing a methionine, while ipamorelin is a small, modified peptide of about seven hundred daltons. They differ substantially in size, polarity and chromatographic retention, so any method that resolves both has to span a wide elution window.
Analytical notes
Each component has its own expected ions and should be reported separately; a single mass result for the preparation does not establish that both are present, still less in what proportion. Tesamorelin is read from its multiply charged series, with the triply, quadruply and quintuply protonated ions near m/z 1711.91, 1284.19 and 1027.55. Ipamorelin is read from the singly and doubly protonated ions near m/z 712.39 and 356.70.
Content is established by chromatographic separation with quantitation of each component against its own reference standard. Because the two peptides differ so much in hydrophobicity, a gradient method is required, and co-elution is unlikely to be the problem; the more common difficulty is detecting the smaller peptide, which has a weaker chromophore than the larger one.
Storage and handling in the laboratory
As supplied, the material is a lyophilized powder, stored at -20 degrees Celsius, sealed and protected from light and moisture. A mixture is only as stable as its least stable component, so storage conditions are set by the more sensitive of the two peptides, and any stability assessment should track both components individually.
For laboratory research use only. Not for human or animal consumption. Not intended to diagnose, treat, cure, or prevent any disease.